Good laboratory practice


In the experimental (non-clinical) research arena, good laboratory practice or GLP is a quality system of management controls for research laboratories and organizations to ensure the uniformity, consistency, reliability, reproducibility, quality, and integrity of products in development for human or animal health (including pharmaceuticals) through non-clinical safety tests; from physio-chemical properties through acute to chronic toxicity tests.[1][2]

GLP was first introduced in New Zealand and Denmark in 1972, and later in the US in 1978 in response to the Industrial BioTest Labs scandal. It was followed a few years later by the Organization for Economic Co-operation and Development (OECD) Principles of GLP in 1992; the OECD has since helped promulgate GLP to many countries.

GLP applies to non-clinical studies conducted for the assessment of the safety or efficacy of products in development (including pharmaceuticals) for people, animals, and the environment.[1] GLP, a data and operational quality system, is not the same as standards for laboratory safety – appropriate gloves, glasses and clothing to handle lab materials safely. The principles of GLP aim to ensure and promote safety, consistency, high quality, and reliability of chemicals in the process of non-clinical and laboratory testing. GLP is not limited to chemicals and also applies to medical devices, food additives, food packaging, colour additives, animal food additives, other non-pharmaceutical products or ingredients, biological products, and electronic products.

GLP was first introduced in New Zealand and Denmark in 1972.[3] GLP was instituted in US following cases of fraud generated by toxicology labs in data submitted to the FDA by pharmaceutical companies. Industrial BioTest Labs (IBT) was the most notable case, where thousands of safety tests for chemical manufacturers were falsely claimed to have been performed or were so poor that police investigators could not piece together what work had been done...even though IBT superficially delivered the test results their contracts with the manufacturers specified.[4]

These issues were made public in the hearings at the US Congress, which led to the FDA's publication of Proposed Regulations on GLP in 1976, with establishment of the Final Rule in June 1979 (21 CFR 58). The Environmental Protection Agency (EPA) had also encountered similar problems in data submitted to it, and issued its own draft GLP regulations in 1979 and 1980, publishing the Final Rules in two separate parts (40 CFR 160 and 40 CFR 792) in 1983.[5]: 5 

Following Decision C(97),186/Final of the OECD Council, data generated in the testing of chemicals in one OECD Member Country, in accordance with OECD Test Guidelines and the Principles of GLP are accepted in all other OECD Member Countries.OECD: ENV/MC/CHEM(98)17 part two